SCB13 Dry-Type Transformer for 10 kV Networks

Resin-insulated dry-type transformer with lower losses than SCB11, for indoor distribution.

Factory photograph of a dry-type transformer
Product family photograph. Supplied configuration may differ.

Key facts

Resin-insulated dry-type transformer with lower losses than SCB11, for indoor distribution.

  • 10 kV published voltage class
  • Off-circuit tap changing
  • Epoxy resin insulation
  • 30–2,500 kVA in the published table
Voltage class
10 kV
Frequency
50 Hz
Installation
Indoor

Published normal service conditions: −25 °C to +40 °C; altitude below 1,000 m. Specify site conditions in your enquiry.

Request datasheetTechnical parameters

Lead time confirmed per order.

Technical parameters

Scroll each table horizontally on smaller screens. Values below are from the factory’s published product tables; confirm the final configuration with the technical team.

SCB13-30-2500/10/0.4
Rated capacity (kVA)No-load loss (kW)Load loss (kW)No-load current (%)Impedance (%)
300.1350.6402.04.0
500.1950.9002.04.0
800.2651.2401.54.0
1000.2901.4151.54.0
1250.3401.6651.34.0
1600.3851.9151.34.0
2000.4452.2751.14.0
2500.5152.4850.94.0
3150.6353.1250.84.0
4000.7053.5900.84.0
5000.8354.3900.84.0
6300.9655.2950.74.0
6300.9355.3650.76.0
8001.096.2650.76.0
10001.277.3150.76.0
12501.508.7200.76.0
16001.7610.5550.76.0
20002.1913.0050.66.0
25002.5915.4450.66.0
SCB13-30-2500/10/0.4 voltage and connection options
Rated capacity (kVA)High voltage (kV)HV tapping range (source notation)Low voltage (kV)Connection group
306 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
506 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
806 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
1006 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
1256 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
1606 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
2006 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
2506 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
3156 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
4006 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
5006 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
6306 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
6306 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
8006 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
10006 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
12506 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
16006 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
20006 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11
25006 / 6.3 / 10 / 10.5 / 11±5% or ±2×2.5%0.4Yyn0 / Dyn11

Slash-separated entries are alternatives. Tapping notation is retained from the source; where a percent sign or value is absent, request confirmation before selection.

Load-loss reference temperature is stated on the datasheet. Cooling: natural air (AN); forced-air options should be confirmed for the intended duty. Request voltage combinations, tapping range and connection group for your selected rating.